五方面带你了解减少减速电机发热的方法!

来源:http://www.jnmcd.com 发布时间:2018-12-10 浏览:
接触减速机时间久的朋友大家都知道,减速电机工作不久即过热,咱们能够跟据以下五方面来判别并检修减速电机:
Friends who have been in contact with the reducer for a long time all know that the reducer motor will soon overheat. We can distinguish and repair the reducer motor according to the following five aspects:
1.绕组短路。当工作绕组或起动绕组短路时,短路线圈会发生很大的热量,并发出噪声。若减速电机持续工作,热量无法散发,将导致减速电机过热,损坏未短路的绕组。因而,电动机过热时应立即停机查看,依据具体情况采纳相应措施进行修补。
The 1. winding is short circuited. When the working winding or starting winding is short-circuited, the short-circuited coil will generate a lot of heat and noise. If the deceleration motor continues to work, the heat cannot be dissipated, which will lead to the overheating of the deceleration motor and damage the winding without short circuit. Therefore, when the motor is overheated, it should stop immediately to check and adopt corresponding measures to repair according to the specific situation.
2.绕组接地。接地较严峻时后果与短路相同,轻则电动机过热,严峻时烧毁绕组。
The 2. winding is grounded. When grounding is severe, the consequences are the same as short-circuit. When grounding is severe, the motor overheated and the winding burned out.
3.工作绕组与起动绕组碰线短路。当工作绕组与起动绕组碰线短路时,电流经工作绕组流入起动绕组,时刻一长起动绕组就会烧毁。要寻找碰线部位,可将两个绕组别离与减速电机接线端分开,然后将查验灯一端接工作绕组,另一端接起动绕组。
3. Short circuit between working winding and starting winding. When the working winding is short-circuited with the starting winding, the current flows into the starting winding through the working winding, and the starting winding will burn up as soon as the starting winding is long. To find the touching part, two windings can be separated from the terminal of the reducer motor, and then one end of the checking lamp is connected with the working winding and the other end is connected with the starting winding.
若查验灯亮即标明两绕组相碰短路。然后,依次将工作绕组的各极与起动绕组断开,若断开某一极时查验灯熄灭,则标明该极绕组与起动绕组碰线短路。查找碰线处并将其包扎绝缘即可。假如仍无法确定碰线部位,只要将起动绕组的线圈拆开进行查看。
If the inspection lamp is on, the short circuit between the two windings will be indicated. Then, each pole of the working winding is disconnected from the starting winding in turn. If the check lamp is turned off when a pole is disconnected, the short circuit between the pole winding and the starting winding is indicated. Find the touching wire and wrap it for insulation. If it is still impossible to locate the touching position, just take the coil of the starting winding apart for inspection.
4.轴承损坏或短少润滑脂。轴承损坏使定子、转子相擦,或轴承内短少润滑脂,都会使电动机过热。查看轴承,若短少润滑脂,应添加适量润滑脂;假如轴承磨损或损坏,则应替换轴承。
4. Bearing damage or little grease. Damage to bearings causes friction between stators and rotors, or short lubricating grease in bearings can overheat the motor. Look at the bearings, if there is little grease, the appropriate amount of grease should be added; if the bearings are worn or damaged, the bearings should be replaced.
5.过载。减速电机过载时,会因绕组过流而使单相减速电机过热。若负载过重但无法调整,应替换功率较大的电动机。假如过载是因减速电机内部部件相碰、堵塞等造成,则应检修电动机机械部分。
5. overload. When the speed reducer is overloaded, the single-phase speed reducer will be overheated due to the winding overcurrent. If the load is too heavy but cannot be adjusted, the motor with higher power should be replaced. If the overload is caused by the collision and blockage of the internal parts of the decelerating motor, the mechanical part of the motor should be overhauled.
以上就是关于山东微型电机的相关介绍,希望大家看完以后能对以后的生活带来帮助,想要了解更多资讯请点击我们的网站:http://www.jnmcd.com
The above is about the introduction of Shandong micro-motor. I hope you can help your future life after reading it. For more information, please click on our website: http://www.jnmcd.com!