直流无刷电动机出现冒烟是什么情况造成的?

来源:http://www.jnmcd.com 发布时间:2019-05-22 浏览:
1. 电源电压过高,使死心磁通密渡过饱和形成直流无刷电机温升过高:假如电源电压超越规范很多,应与供电部门联络处理。
1. The excessive voltage of the power supply makes the flux density of the dead center over saturated, which results in the excessive temperature rise of the brushless DC motor. If the voltage of the power supply exceeds a lot of specifications, it should be dealt with in liaison with the power supply department.
2. 电源电压过低,在额定负载下直流无刷电机温升过高:若因电源线电压降过大而惹起,可改换较粗的电源线;假如是电源电压太低,可向供电部门联络,进步电源电压。
2. The power supply voltage is too low and the temperature rise of DC brushless motor is too high under rated load. If the voltage drop of the power supply line is too large, the thicker power supply line can be changed. If the power supply voltage is too low, contact the power supply department to improve the power supply voltage.
3.灼线时,死心被灼过,使铁耗增大:做死心检查实验,检修死心,扫除毛病。
3. When the wire is burned, the heart is burned, which increases the iron consumption: do the heart-to-heart inspection experiment, repair the heart, and remove the defects.
4.定转子死心相擦:检查毛病缘由假如轴承间隙超限,则应改换新轴承,假如转轴弯曲,则需调查处置,死心松动或变形时应处置死心,消弭毛病。
4. Dead-center friction between stator and rotor: If the bearing clearance exceeds the limit, new bearings should be replaced. If the rotating shaft is bent, investigation and disposal should be carried out. Dead-heart should be disposed of when the dead-center is loose or deformed to eliminate the defects.
5.绕组外表粘满尘垢或异物,影响直流无刷电机散热:打扫或清洗直流无刷电机,并使直流无刷电机通风沟畅通。
5. The winding is covered with dirt or foreign matter, which affects the heat dissipation of the brushless DC motor: cleaning or cleaning the brushless DC motor, and making the ventilation ditch of the brushless DC motor unblocked.
山东无刷电机
6.直流无刷电机过载或拖动的消费机械阻力过大,使直流无刷电机发热:扫除拖动机械毛病,减少阻力,依据电流指示,如超越额定电流,需减低负载,改换较大容量直流无刷电机或采取增容措施。
6. The excessive resistance of consumption machinery caused by overload or dragging of DC brushless motor makes DC brushless motor heat up: sweep away traction mechanical faults and reduce resistance. According to current indication, if exceeding rated current, load should be reduced, large capacity DC brushless motor should be replaced or capacity-increasing measures should be taken.
7.直流无刷电机频繁起动或正反转次数过多:减少直流无刷电机起动及正、反转次数或改换适宜的直流无刷电机。
7. Frequent starting or excessive number of positive and negative turns of brushless DC motors: reduce the number of starting and positive and negative turns of brushless DC motors or change suitable brushless DC motors.
8.笼型转子断条或绕线转子绕组接线松脱,直流无刷电机在额定负载下转子发热,使直流无刷电机温升过高:查明断条和松脱处,重新补焊或扭紧固定螺丝。
8. Cage rotor broken bar or winding loosening of rotor wiring, DC brushless motor under rated load rotor heating, so that DC brushless motor temperature rise too high: find out the broken bar and loosening, re-welding or tightening the fixed screw.
9.绕组匝间短路相间短路以及绕组接地:按本表序号1.
9. Interturn Short Circuit, Interphase Short Circuit and Winding Grounding: Number 1 in this table.
10.进风温渡过高:检查冷却系统安装能否有毛病,检察四周环境温度能否正常。
10. Excessive high intake temperature: check whether the cooling system installation is defective, check whether the ambient temperature around can be normal.
11.风扇毛病,通风不良:检查直流无刷电机风扇能否损坏,扇叶能否变形或未固定好。必要时改换风扇。
11. Fan faults, poor ventilation: check whether the DC brushless motor fan can be damaged, whether the fan blade can be deformed or not fixed properly. Change the fan if necessary.
12.直流无刷电机两相运转:检查溶丝,开关接触点,扫除毛病。
12. Two-phase operation of DC brushless motor: check the dissolve wire, switch contact point, and remove defects.
13.重绕后绕组浸渍不良:要采取二次浸渍工艺,最好采用真空浸渍措施。
13. Bad impregnation of windings after rewinding: vacuum impregnation is the best method to adopt secondary impregnation process.
14.环境温度增高或直流无刷电机通风道梗塞:改善环境温度,采取降温措施,隔离直流无刷电机左近高温热源,防止直流无刷电机在日光下暴晒。
14. Enhanced ambient temperature or blockage of DC brushless motor ventilation duct: Improve ambient temperature, take cooling measures, isolate the left and near high temperature heat source of DC brushless motor, prevent DC brushless motor from exposure to sunlight.
15.绕组接线错误:Y联合直流无刷电机误接成△联合,或△联合直流无刷电机误接成Y联合要矫正接线。
15. Winding wiring errors: Y-joint brushless DC motor incorrectly connected to joint, or joint brushless DC motor incorrectly connected to joint to correct wiring.